Today I arrived on site and performed a winter time tune up on the system. Here's a breakdown of the work completed: **System Assessment:** * Overall equipment condition is fair. * Indoor unit is located in the closet. * Outdoor unit is located in the back yard. * The unit services the whole home. **Component Inspections & Testing:** * Checked the pleated 1" filter (18x18). Customer will replace it themselves. * Indoor and outdoor coils are in fair condition. * Verified proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring. * Blower wheel, secondary drain pan, primary drain pan, and electrical wires are secured and in good condition. * Condensate drain line is strapped. **Maintenance Actions:** * Cleared the drain line. * Cleaned out the primary and secondary pans. * Tested the safety switch. * Dusted the thermo