Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic - West Side):** * Replaced the pleated 1" filter (20x20x1). Customer provided the spare filters. * Confirmed the indoor coil is in good condition. **Outdoor Unit (Heat Pump on Side of House):** * Observed the outdoor coil is in fair condition. * Verified proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, and contactor. * Confirmed the blower wheel, secondary drain pan, primary drain pan, and electrical wires are secured and in good condition. **System Performance:** * Measured a return air temperature of 75.0°F and a supply air temperature of 106.0°F. * Cleared the condensate drain line and tested the safety switch. * Confirmed the drain line is strapped. * Tested thermostat operation and restored power to the units. Today I arrived on site and performed