Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic):** * Checked the pleated 1" filter (20x20x1) and noted its condition as fair. * Observed the indoor coil to be in fair condition. **Outdoor Unit (Heat Pump on Side of House):** * Observed the outdoor coil to be in fair condition. * Tested and inspected the following electrical components, all operating within manufacturer's specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring * Inspected the secondary and primary drain pans, and secured electrical wires. All were found to be in good working order. * Confirmed the condensate drain line is connected and strapped. * Cleared the condensate drain line. **System Performance:** * Measur