Aidan D.

Aidan D.


Job Checkin

Today I arrived on site and performed a winter time tune up on your system. Here's a summary of the work completed: **Indoor Unit (Furnace in Closet - East Side):** * Replaced the pleated 1" filter (20x20x1). Customer provided spare filters. * Confirmed the indoor coil is clean. **Outdoor Unit (Straight Cool on Side of House):** * Confirmed the outdoor coil is clean. **Electrical Components (Tested and Working):** * Verified proper operation and amperage of: Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Defrost Control Board, and Electrical Wiring. **System Components (Inspected and Working):** * Confirmed good condition and proper operation of: Blower Wheel, Ductwork, Electrical Wires Secured, and Primary Drain Pan. **Condensate Drain System:** * Cleared the drain line, cleaned out the primary pan, and tested the safety switch. Flushed with drain solvent. The drain line