Job Checkin

Today I arrived on site and performed a winter time maintenance on your HVAC equipment. System Assessment: Overall equipment condition: Fair. Indoor unit located in the attic closet; it's a furnace. Outdoor unit located on the side of the house; it's a straight cool unit. System services the upstairs area. Component Inspections & Testing: Electrical components (Blower Motor, Inducer Draft Motor, Condenser Fan Motor, Blower Run Capacitor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, Electrical Wiring) tested and working within manufacturer's specifications. Inspected components (Blower Wheel, Burners, Exhaust Flue, Heat Exchanger, Primary Drain Pan, Electrical Wires Secured, Ductwork) are in good condition and working properly. Carbon Monoxide test: 0.00 PPM. Return Air Temperature: 65.0 Degrees Fahrenheit. Supply Air Temperature: 116.0 Degrees Fahrenheit. Maintenance Actions: Cleared condensate drain line and cleaned out primary pan. Confirmed drain line is st