As I arrived, the tenants were inside the home both girls told me that it’s on and running and the outside condenser is running i noticed walking up to the apt. , but they don’t feel any air so I went up to the access where the return is cut into and found that the horizontal breaker is making popping and crackling sounds also intermittent on and off on the high voltage because of that The blower is not getting its high voltage to turn on causing the coil to freeze up also due to the filter being clogged as it is this regularly needs to be changed once a month I highly recommend To ensure this doesn’t happen again. A big part of all this happening and the breaker overheating and burning out is due to Improper filter change As the high voltage from that blower and everything else is on the other side of the horizontal breaker it does show signs corrosion And overheating as a safety I’ve left this off please be aware after we do this breaker change that they’re also might be some other