Found system has a burned fuse, quoted to trace and locate a low voltage short in the system and maintenance membership to get discounts, maintenance visits and priority on calls, quoted was accepted, diagnosed system and found contactor coil is border line bad could be what caused the 3 amp fuse to burn out, corrected condenser motor run capacitor from a 7.5 microfarads to the 5 microfarads that is required, condenser motor has taken some damage, went over the low voltage wiring and couldn’t locate a short to ground at this time, replaced fuse and tested system, all came back and system became operational, left system running in cooling at my departure, thank you for choosing total air. Future repair contactor and condenser motor will quote at that time of failure.