Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Located in the garage/attic. * Checked the pleated 1" filter (20x20). * Observed the filter condition. * Determined the indoor coil was in fair condition and clean. **Outdoor Unit (Heat Pump):** * Located on the side of the house. * Determined the outdoor coil was in good condition and clean. **Electrical Components:** * Tested and inspected the blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, compressor start capacitor, contactor, and electrical wiring; all are working properly within manufacturer's specifications. **System Components:** * Inspected the blower wheel, secondary drain pan, primary drain pan, and secured electrical wires; all are in good condition and working properly. **Measurements & Adjustments:** * Measured a return air temperature of 72.0°F and a supply air temperature of 53.0°