Today I arrived on site and performed a winter time tune up on your system, confirming it is currently working properly. **Indoor Unit (Air Handler in Garage):** * Verified the indoor coil is clean and in good condition. * Replaced the antimicrobial filter with a spare provided by the customer. **Outdoor Unit (Heat Pump on Side of House):** * Confirmed the outdoor coil is clean and in good condition. **Electrical Components (Tested and Working):** * Verified proper operation and amperage within manufacturer specifications for: blower motor, condenser fan motor, heat strip kit, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, defrost control board, and electrical wiring. **System Components (Inspected and in Good Condition):** * Confirmed the blower wheel, ductwork, electrical wires, primary drain pan, and secondary drain pan are in good condition and working properly. **Condensate Drain System:** * Cleared the drain line. *