Robert B.

Robert B.


Job Checkin

Today I arrived on site and performed a summer tune-up on the system. Here's a summary of the work completed: **System Assessment:** * Overall equipment condition assessed as fair. * Indoor unit located in the crawl space. * Outdoor unit located in the back yard. * Unit services the whole home. **Component Inspections & Testing:** * Filtration: Washable filter, size 20x20, washed and checked. * Indoor and outdoor coils are in fair condition. * Verified proper operation of electrical components: Blower Motor, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Compressor Start Capacitor, Contactor, and Electrical Wiring. * Inspected and confirmed the proper function of: Blower Wheel, Secondary Drain Pan, Primary Drain Pan, and Secured Electrical Wires. * Return air temperature: 66.0 Degrees Fahrenheit. * Supply air temperature: 110.0 Degrees Fahrenheit. **Condensate Drain System Service:** * Cleared the drain line.