Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Indoor Unit (Furnace): Located in the closet. Filter: 20x25x5 washable filter was washed. Indoor coil condition: Fair. Outdoor Unit (Straight Cool): Located in the back yard. Outdoor coil condition: Fair. Electrical Components (Tested and Working): Inducer Draft Motor, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Compressor Start Capacitor, Contactor, Defrost Control Board, Furnace Control Board, Electrical Wiring. Components Inspected (Good Condition): Blower Wheel, Burners, Exhaust Flue, Heat Exchanger, Primary Drain Pan, Electrical Wires Secured, Ductwork. System Performance: Carbon Monoxide: 0.00 PPM. Return Air Temperature: 72.0 Degrees Fahrenheit. Supply Air Temperature: 112.6 Degrees Fahrenheit. Condensate Drain System: Cleared drain line and tested safety switch. Drain line is strapped. Other Actions: Restored power to the units.