Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler in Attic):** * Replaced the 20x25x5 pleated filter. * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump on Side of House):** * Verified the outdoor coil is clean and in good condition. * Tested and inspected the blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring; all are working properly within manufacturer's specifications. **System Components:** * Inspected the blower wheel, primary drain pan, and electrical wires; all are secured and in good condition. * Cleared the condensate drain line and cleaned out the primary pan. * Tested the safety switch. * Return air temperature: 74.0°F. * Supply air temperature: 100.0°F. * Confirmed the drain line is strapped. **Additional Actions:** * Dusted the thermostat. * Restored pow