Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Indoor Unit (Air Handler in Attic/Garage): Observed the indoor unit to be in fair condition. Confirmed the filter is a pleated 2-6" type, size 213. Observed the indoor coil to be in fair condition. Outdoor Unit (Heat Pump on Side of House): Observed the outdoor unit to be in fair condition. Observed the outdoor coil to be in fair condition. Electrical Components: Tested and confirmed proper operation of: Blower Motor Condenser Fan Motor Compressor Blower Run Capacitor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring Heat Strip Kit System Components: Inspected and confirmed good condition and proper operation of: Blower Wheel Primary Drain Pan Electrical Wires Secured Ductwork System Readings & Adjustments: Measured a return air temperature of 74.0°F and a supply air temperature of 109.0°F. Cleared the condensate drain line and cleaned out the primary pan. Confirmed the dra