Today I arrived on site and performed a winter tune-up on your system. Here's a summary of the work completed: **Indoor Unit (Furnace - Garage):** * Replaced the 20x25 pleated filter. * Observed the indoor coil to be in fair condition. * Tested and inspected the blower motor, inducer draft motor, furnace control board, and electrical wiring; all are working within manufacturer's specifications. * Inspected the blower wheel, burners, exhaust flue, heat exchanger, primary drain pan, electrical wires, and ductwork; all are in good condition and working properly. * Measured a return air temperature of 72.0°F and a supply air temperature of 140.0°F. * Tested the condensate drain system safety switch. * Confirmed the drain line is strapped. **Outdoor Unit (Heat Pump - Side of House):** * Cleaned the outdoor coil, which was in fair condition. * Tested and inspected the contactor, and it is working within manufacturer's specifications. * Restored power to the units. *