Today I arrived on site and performed a winter time tune up on your system. Here's a summary of the work completed: **Filtration:** * Replaced the pleated 1" filter in the attic unit (12x12 size) using the customer's spare filters. * Checked the new filter. **Condensate Drain System:** * Cleared the condensate drain line. * Cleaned out the primary and secondary drain pans. * Tested the safety switch. * Confirmed the drain line is strapped and secured. **Electrical Components (Tested and Working):** * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Electrical Wiring **Components Inspected (Good Condition):** * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires Secured **Additional Actions:** * Dusted the thermostat and tested its operation. * Restored power to the units. **System Performance:** * Return