Today I arrived on site and performed a winter tune-up on your system. Here's a summary of the maintenance activities: **Indoor Unit (Air Handler in Closet):** * Verified the air handler's condition as good. * Checked and washed the washable 20x20x4 filter. * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump on Side of House):** * Verified the outdoor coil is in good condition. **Electrical Components:** * Tested and confirmed proper operation of the blower motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, defrost control board, and electrical wiring. **System Components:** * Inspected and confirmed the blower wheel, heat exchanger, primary drain pan, and electrical wires are secured and in good working order. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary pan. * Tested the safety switch. * Confirmed the drain line is strapped. **Measurements