I performed an AC maintenance service on a residential unit. I started by inspecting the air filter, which needed replacement, so I installed a new 16x25x1 MERV 11 filter. Next, I checked the refrigerant levels with a manifold gauge and cleaned the evaporator coil using a foaming coil cleaner. Finally, I measured the temperature differential across the system to ensure it was cooling efficiently.