Travis was wonderful and I really appreciate all of his help servicing my unit.
Emerson communicated the issue we had and added necessary refrigerant
Travis arrived on time and provided thoughtful guidance on how best to modify our AC system
Gene is an excellent communicator. I really appreciated his professionalism.
Great communication before and during visit. Found the solution and fixed the problem. Gene was terrific.
Gene was awesome with my annual winter service! Very knowledgeable, nice and respectful. Thank you Gene and Centex.
Gene was on time, friendly, professional, answered all our questions. He also spent time showing us how to make adjustments on the ecobee. I especially appreciate the detailed reports which give me confidence my unit is in good condition and working as it should be.
Gene went out of his way to explain the thermostat programming and point out CO detector issues!
I loved the detailed explanation as much as the expertise and service itself. Getting behind the tech speak to understand what the situation really is is very important to me.
Used info from recent alerts to produce diagnosis. Covered all bases. Wore mask, as I had been traveling and wore one also. Did a LOT of work and left no trace of a mess, very clean, very attentive.
Response from Centex Air & Heat:
Thank you so much for this great 5-star review. We really appreciate your business and helping to share the word about us.
Another Bi-annual checkup. Another year of no worries and no issues with the AC and Heating at our rental property.
Upon arrival we found the indoor head unit would run for about 5 mins and then shut off and throw a constant code. The code was stating the outdoor condensing unit wasn’t sending signal back to the indoor head unit after 5 minute causing shutdown. After inspecting the outdoor unit inverter board burned up. Let customer know the issue and gave him options. The board is 5-6 weeks out, the customer wants a bid for a new system if the board cannot be delivered and installed soon. .
Upon my arrival I spoke with the customer about their concerns with the comfort control being blank. Performing my diagnostics I found that the water removal system has become restricted causing the auxiliary float safety switches to trip as well as leaked into the emergency drain pan under the fresh air control. I spoke with the customer about my concerns and presented repair options to be performed while on site. Customer approved to have the water removal system cleared, treated and the emergency drain pan drained. I performed the approved repairs by clearing the water removal system, installing another ball valve to allow sections of the 2 drain lines, treated the system then tested the system. I found everything properly at this time. I will be getting a quote put together Monday morning on renovations of the drain line to allow for new pvc to be installed that is clear of all zooglea.
Upon my arrival I performed the approved repairs in the upgrading power protection and the air circulation system renovation. On both systems I installed new power protection, pulled the air movement system to break down for chemical cleaning. After cleaning was performed and air movement system dried out I installed it back into the system then ran a performance and safety testing on both systems finding everything is operating within manufacture specifications at this time.
Upon my arrival on the approved repairs of upgrading the power protection system. Installed new power protection at the indoor furnace and redid wire terminals, installed new disconnect, power protection, redid wire terminals, new electrical fittings and sealed around the disconnect. I then tested the system finding it operating properly at this time. While performing the repair I found that the breaker on the outdoor system is oversized using a 60 amp when the unit calls for a 40amp. I brought this to the customers attention and he will have an electrician install the proper breaker.
Performed cooling evaluation on one infinity. Heat pump system. Clear drain line and treated with anti-microbial spray. Checked all functions and found everything working to manufacture specifications. Removed T fin from line. Set on outside of home near condenser as approved by Daryl and homeowner. Washed condenser coils.
Performed installation of factory specified compressor and thermostatic expansion valve. Installed new filter dryer at condenser. Performed system vacuum to 700 µm and recharged system to specs with R410a. Washed down condenser coil and obtain 17° temperature differential. Unit is operating to manufacture specifications at this time.
Upon my arrival I performed a 6 month checkup on 1 straight cool furnace system. Flushed and treated the water removal system, washed the condenser coil using water, cleaned and treated the electrical cabinet with electrical insecticide, replaced the air filter then verified systems safety and performance. I found everything to be operating within the manufacture specifications at this time.
Upon my arrival I performed the approved repairs on the zoned system. I removed the failed comfort control circuit, both dampers, installed new comfort control circuit, installed new 16x16” PO/PC damper and new 12” round PO/PC damper, redid wire terminals, sealed around both dampers then ran a performance and safety testing. I found both zones operating properly when there is a demand called for and when the demand is no longer called for allowing the dampers to open and close as they should. I verified system had a good Delta T across the coil, tested the amp draws and electrical comments inside and out, and checked systems pressures. Given its 90° in the home it was difficult to acquire and accurate pressure reading. With the temperature split being good we will verify the pressures again at the Bi-annual maintenance inspection once the home is at a normal operating temperature inside. I also found that the voltage enhancement system on the outdoor unit was just sitting in the box. I
Upon my arrival I performed a 6 month checkup on 1 straight cool furnace system. Flushed and treated the water removal system, washed the condenser coil using water, cleaned and treated the electrical cabinet with electrical insecticide, replaced both air filters then verified system safety and performance. I found everything operating within manufacture specifications at this time.
Upon my arrival I performed a 6 month checkup on 2 RTU package units. Flushed and treated water removal systems, washed condenser coil using water, cleaned and treated electrical cabinets, changed all air filters then verified system safety and performance. I found RTU#1 to be operating within manufacture specifications. RTU#2 I found bacterial growth inside the blower cabinet and on the blower wheel. I recommend having the air movement system pulled to be disassembled for chemical cleaning. I also recommend adding power protection to both systems to prevent any failures caused by power outages, brown outs or voltage spikes. options will be emailed over for review.
Upon my arrival, I performed a six month check up on one straight, cool furnace system. Flush and treated the water remove system, washed the condenser coil using water, cleaned and treated the electrical cabinet, replaced the air filter then verified systems safety and performance. I found everything on the system operating within manufacture specifications at this time. During the evaluation I did find that the power protection at the indoor and outdoor units are no longer working. I went over my concerns with the customer and he approved HT4C. 10% was collected today and a return will be scheduled.
Upon my arrival I spoke with the customer about their concerns with the system not cooling. Performing my diagnostics I found the comfort control circuit system is faulted not sending cool call to the indoor system. I spoke with the customer about their repair options and went over maintenance. Customer approved repairs today and signed the rental on to out maintenance program. Return will have to be scheduled preferably in the morning since this is an attic systems. Customers gave door code and gate code to gain access to the home since it is unoccupied and they may not be in town.
Upon my arrival I checked into the concerns with the back system not cooling properly. Performing my diagnostics I found the pressures and temp split were good. I checked the vents and found that a few of them were shut down to allow more airflow to the daughter’s room. I helped the customer with balancing the vents to allow airflow to all areas and informed her they may have to make adjustments as they go. Currently all areas are cooling well. There are no blinds in the daughter’s room allowing sunlight to enter as well. I advised on blinds and blackout curtains.
Upon my arrival I evaluated 1 furnace system & 1 mini split system 2 heads & 1 outdoor unit. I verified system safety and performance is to manufacture specifications. Flushed and treated the water removal system. Cleaned the electrical cabinet and washed unit using water. Found the upstairs minisplit head filter extremely dirty with debris. I cleaned both the upstairs and downstairs filters . I recommend uv lights for both heads.
Upon my arrival I evaluated 2 furnace systems. I verified system safety and performance is to manufacture specifications. Flushed and treated the water removal system. Cleaned the electrical cabinet and washed unit using water. Found the pressures low for the downstairs unit, . Recommended a leak search, Carl chose to only add r410a at this time. I added 4LB’s.