Upon my arrival I performed the approved repairs of a complete disassembled and chemical clean on 1 mini split system. I disassembled the mini split system removing the air movement system, the drain pan and main cover. I then installed the bib kit to prevent any water leaking on to the floor. Sprayed the heat transfer media coil with Viper coil cleaner on both sides, sprayed the air movement system and drain pan with viper coil cleaner, washed the heat transfer media coil with portable power washer after allowing a good soak period, washed the drain pan and air movement system with water house outside the building, flushed the water removal system, installed bio protect then reassembled the system and verified its operations. System is performing well at this time and has increased air flow after the deep clean.