Upon my arrival in Muldoon I spoke with the homeowner about the work that is going to be performed today and verified access in and out of the home. I then proceeded to start to perform the repair. We recovered all of the refrigerant from the system, removed the faulted refrigerant pressure control, flushed the line set with RX11, installed the new refrigerant pressure control, purged the system with nitrogen while brazing, installed new inline filter dryer then pressure tested the system with nitrogen to verify no leaks. Once the pressure test passed we evacuated the nitrogen and put the system into a vacuum. While the system was coming down to the proper vacuum. While the system was going to vacuum we installed a new voltage enhancement system, voltage distribution system and redid all wire terminals. Added me Armaflex to the suction line at the outdoor condenser. Once the system came down to a proper vacuum and passed the DK test we added new refrigerant to the system.