Upon my arrival in Rosanky, for an AC repair, I spoke with the customer about their concerns with the system running and not cooling. Starting my diagnostics at the indoor system I found the indoor coil is restricted and dirty. I moved to the outdoor system and verified the voltage enhancement system was good. Once this was verified I supplied high voltage to the system and only the exhaust removal system came on. I tested the refrigerant circulation pumping system to ground and across the start, run and common terminals. I found I was getting OL from the run to common, OL from the start to run and 1.8 ohms from start to common. This is an indication that the refrigerant circulation pumping system is mechanically faulted. The most likely cause of this is due to the restricted coil and the return air being having stuff stacked in front of it. This would cause the system to not create vapor saturation and lead to liquid refrigerant returning to the refrigerant circulation pumping system.