Corey B.

Corey B. Job Checkin

This is the most basic equipment available for purchase today. It uses a single speed compressor and a single speed indoor fan. This unit is the least expensive to initially purchase and install.

This is the most basic equipment available for purchase today. It uses a single speed compressor and a single speed indoor fan. This unit is the least expensive to initially purchase and install.

Berry D.

Berry D. Job Checkin

Downstairs system control board shorted, ECM fan motor shorted heat strip shorted

Downstairs system control board shorted, ECM fan motor shorted heat strip shorted

Corey B.

Corey B. Job Checkin

System is up and running and cooling and heating ready for inspection

System is up and running and cooling and heating ready for inspection

Corey B.

Corey B. Job Checkin

Air handler control board on heating cuts out loses connection, so need to order a control board for the air handler

Air handler control board on heating cuts out loses connection, so need to order a control board for the air handler

Corey B.

Corey B. Job Checkin

They need to come and change out the other board Wednesday

They need to come and change out the other board Wednesday

James T.

James T. Job Checkin

Today James visited to complete a drawing of the home to provide duct replacement information. The drawing is complete and the airflow design will be done after approval for the project.

Today James visited to complete a drawing of the home to provide duct replacement information. The drawing is complete and the airflow design will be done after approval for the project.

Brennan  G.

Brennan G. Job Checkin

Brennan G I set the fan speed back on high per client request

Brennan G
I set the fan speed back on high per client request

Brennan  G.

Brennan G. Job Checkin

Brennan. G Todays visit was for a system maintenance. The system is mostly clean and all the electrical is within specs. Refrigerant levels are within range. Cleared the drain line and sanitized the air handler. Replaced all 12x12 filters inside the home. I discovered some mildew forming inside the air handler, sprayed with non rinse cleaner and wiped as much of it of as i could. Found the compressor is drawing high start and run amps. Discussed installing a compressor saver and a air purifier to remedy these concerns.

Brennan.  G
Todays visit was for a system maintenance.
The system is mostly clean and all the electrical is within specs.
Refrigerant levels are within range.
Cleared the drain line and sanitized the air handler.
Replaced all 12x12 filters inside the home.
I discovered some mildew forming inside the air handler, sprayed with non rinse cleaner and wiped as much of it of as i could.
Found the compressor is drawing high start and run amps.
Discussed installing a compressor saver and a air purifier to remedy these concerns.

Brennan  G.

Brennan G. Job Checkin

Brennan G Todays visit was for the system still dripping water. Cleared water from emergency pan and vacuumed the drain. Will follow up with James on what we need to do next. Informed Rula we will call her back to schedule the next visit

Brennan G
Todays visit was for the system still dripping water.
Cleared water from emergency pan and vacuumed the drain.
Will follow up with James on what we need to do next. 
Informed Rula we will call her back to schedule the next visit

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

Repair Option

Repair Option

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Pressurized primary drain line clearing blockage.

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Pressurized primary drain line clearing blockage.

Brennan  G.

Brennan G. Job Checkin

Brennan G Todays visit was to investigate why the air handler leaks water into the emergency pan. Upon arrival , the emergency pan had water inside of it , although was not filled all the way or high enough to engage the float sensor. Ran system in cooling mode for appx 30 minutes and did not see any water drip from the air handler. Added a cap to the t fitting access at the air handler and turned the 45 elbow at the end of the line faced upward to “trap” the drain. Checked static pressure before and after the filter, there is only a 0.05in different across the filter. After making changes to the drain (adding a trap fitting and a cap fitting) the drain is producing much more water then before. Watched system run in cooling for about an hour , never saw any water drip from the air handler.

Brennan G
Todays visit was to investigate why the air handler leaks water into the emergency pan.
Upon arrival , the emergency pan had water inside of it , although was not filled all the way or high  enough to engage the float sensor. Ran system in cooling mode for appx 30 minutes and did not see any water drip from the air handler.
Added a cap to the t fitting access at the air handler and turned the 45 elbow at the end of the line faced upward to “trap” the drain.
Checked static pressure before and after the filter, there is only a 0.05in different across the filter.
After making changes to the drain (adding a trap fitting and a cap fitting) the drain is producing much more water then before.
Watched system run in cooling for about an hour , never saw any water drip from the air handler.

charles@hot2coldairconditioning.com

charles@hot2coldairconditioning.com Job Checkin

Repair Option install new float switches as instructed primary and secondary in the drain pan

Repair Option install new float switches as instructed primary and secondary in the drain pan

Geraldo R.

Geraldo R. Job Checkin

We need a 35 amp breaker for the air handler. Label the equipment system #1 not disconnect. We need to brace both sides of the unit up high to the wall. Can be midway to avoid window.

We need a 35 amp breaker for the air handler. Label the equipment system #1 not disconnect. We need to brace both sides of the unit up high to the wall. Can be midway to avoid window.

James T.

James T. Job Checkin

Today we visited to determine why the unit isn’t draining properly. Based on our previous efforts it seems the drain line has a double-trap or needs more pitch. The outside trap was removed today and the unit seems to be draining well. We should return at the end of this week to see if the issue is resolved or if the drain line needs more pitch.

Today we visited to determine why the unit isn’t draining properly. 

Based on our previous efforts it seems the drain line has a double-trap or needs more pitch. The outside trap was removed today and the unit seems to be draining well. 

We should return at the end of this week to see if the issue is resolved or if the drain line needs more pitch.