James T.

James T. Job Checkin

Inverter technology delivers the most efficient and comfortable home. Sometimes called variable speed systems these machines are like having dozens of differently sized a/c units all in one. They have a variable speed compressor that incrementally “throttles” the power being used. Expect even temperatures, low bills, and extraordinary air quality.

Inverter technology delivers the most efficient and comfortable home. Sometimes called variable speed systems these machines are like having dozens of differently sized a/c units all in one. They have a variable speed compressor that incrementally “throttles” the power being used. Expect even temperatures, low bills, and extraordinary air quality.

James T.

James T. Job Checkin

Today we visited to perform a system maintenance as part of our Fall Promotion. The unit is in good shape and working okay. We did learn the unit is not properly charged with refrigerant although it is still performing well. It seems the charge was not adjusted after the installation because James was not able to locate a leak.

Today we visited to perform a system maintenance as part of our Fall Promotion. 

The unit is in good shape and working okay. We did learn the unit is not properly charged with refrigerant although it is still performing well. It seems the charge was not adjusted after the installation because James was not able to locate a leak.

James T.

James T. Job Checkin

Today we visited to follow up with the recent installation. The new machine looks great and is running properly. Brett mentioned how much quieter the system is and the rooms that used to be warm are now cooling evenly. The project is ready for inspection.

Today we visited to follow up with the recent installation. 

The new machine looks great and is running properly. Brett mentioned how much quieter the system is and the rooms that used to be warm are now cooling evenly. 

The project is ready for inspection.

James T.

James T. Job Checkin

• This machine is the least expensive to initially install. It uses a single stage compressor and indoor blower motor. This unit is the most similar to the current system.

• This machine is the least expensive to initially install. It uses a single stage
compressor and indoor blower motor. This unit is the most similar to the current system.

James T.

James T. Job Checkin

Install Monday 12,000

Install Monday  12,000

Corey B.

Corey B. Job Checkin

3 portable AC window unit installed.

3 portable AC window unit installed.

James T.

James T. Job Checkin

Today we visited to provide pricing to replace the air conditioning system.

Today we visited to provide pricing to replace the air conditioning system.

Brennan  G.

Brennan G. Job Checkin

Brennan G Today I visited for the office mini split not cooling. I found that it was reading an error code (ea) for faulty four way valve (reversing valve). I reset power to the equipment and it is now functioning normally. Unsure what caused this error message , informed Dan if this reoccurs we will likely need to replace the valve.

Brennan G 
Today I visited for the office mini split not cooling.
I found that it was reading an error code (ea) for faulty four way valve (reversing valve).
I reset power to the equipment and it is now functioning normally.
Unsure what caused this error message , informed Dan if this reoccurs we will likely need to replace the valve.

Corey B.

Corey B. Job Checkin

Technician performed full system maintenance check up. Inspected all electrical connections and components. Checked amperage draw for compressor and fan motors. Checked refrigerant charge and found it to be at the proper level. Inspected condenser and evaporator coils. Fully flushed and cleaned drain line. Air filter is clean. Rinsed off condenser coil. System was fully tested and no issues were found. System is running and cooling properly at this time without any issues.

Technician performed full system maintenance check up. Inspected all electrical connections and components. Checked amperage draw for compressor and fan motors. Checked refrigerant charge and found it to be at the proper level. Inspected condenser and evaporator coils. Fully flushed and cleaned drain line. Air filter is clean. Rinsed off condenser coil. System was fully tested and no  issues were found. System is running and cooling properly at this time without any issues.

Corey B.

Corey B. Job Checkin

- Replacement of the leaking accumulator tank - Replacement of the refrigerant muffler - Recharge the system with refrigerant (R-410a)

- Replacement of the leaking accumulator tank 
- Replacement of the refrigerant muffler
- Recharge the system with refrigerant (R-410a)

Corey B.

Corey B. Job Checkin

Unit side discharge port needs to be re-flared, and recharged for proper operations.

Unit side discharge port needs to be re-flared, and recharged for proper operations.

Corey B.

Corey B. Job Checkin

Fixed outdoor flare connection, and recharged the unit with 4 lbs of 410A. System is fully operational at this time. (Service Warranty)

Fixed outdoor flare connection, and recharged the unit with 4 lbs of 410A. System is fully operational at this time. (Service Warranty)

James T.

James T. Job Checkin

Today we visited to reevaluate the system. During the first appointment the technician discovered the unit to be low on refrigerant. We learned the outside unit has a few leaks. The accumulator is leaking and the muffler. The muffler is leaking because a low voltage line rubbed the copper and looks to have arced and burned a small hole. We will call to arrange the repair once the parts are delivered.

Today we visited to reevaluate the system. During the first appointment the technician discovered the unit to be low on refrigerant. We learned the outside unit has a few leaks. The accumulator is leaking and the muffler. The muffler is leaking because a low voltage line rubbed the copper and looks to have arced and burned a small hole. 

We will call to arrange the repair once the parts are delivered.

Corey B.

Corey B. Job Checkin

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Upon arrival found evaporator coil and condenser unit froze. It’s leak I couldn’t find it because the ice. I told customer we coming back tomorrow, Customer pay $79 for service call and I told it will be credit on the repair or new AC unit.

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Upon arrival found evaporator coil and condenser unit froze. It’s leak I couldn’t find it because the ice. I told customer we coming back tomorrow, Customer pay $79 for service call and I told it will be credit on the repair or new AC unit.

Corey B.

Corey B. Job Checkin

Found a shorted 45/5 MFD causing the fan motor to overheat. Replaced faulty part, and checked unit operations. Unit is fully operational at this time. Recommended a preventative maintenance to the homeowner to extend the system life.

Found a shorted 45/5 MFD causing the fan motor to overheat. Replaced faulty part, and checked unit operations. Unit is fully operational at this time. Recommended a preventative maintenance to the homeowner to extend the system life.