1503 U.S. 301
Tampa, FL 33619
813-580-8800

Local Reviews
for pinellas park, fl

Rated 4.8 out of 5 stars based on 8 customer reviews

Excellent service by Troy

Troy was awesome

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent information gathering

I really enjoyed talking with Troy the technician regarding different options. Also, explained how important it is to have an experienced installation crew. He wasn’t trying to push a sell and respected my wants and needs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

James is great!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Courteous and honest

  • Overall Experience
  • Quality
  • Price
  • Convenience

Compressor Plate

Just found the metal plate that am guessing goes over the compressor, leaning against house. Not good. Was not informed of what needed to be done beforehand. Did not receive an invoice for said work done, although I did call and woman who answered emailed it out right away, very appreciated. Did very good job on drain pipe, not sure if inside unit was opened to fix clog.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service awesome tech

Awesome experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pinellas park, fl

Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Customer called us out to get a quote on a new compressor for the unit he has. Customer has a 2 ton Goodman heat pump. Customer had another company come out to diagnose the issue and Troy corroborated the diagnosis of needing a new compressor. As to the cause of why the compressor seized it looks that the fins on the edge of the Compression unit are clogged up and there’s a lot of foliage on one side, which is restricting airflow coming into cool off the compression bulb. Customer is looking to get one more house to come out and give them a quote on the compressor. Quoted customer on a warranty 2 ton compression bulb as he is still under the Goodman warranty, but he is outside of the gap warranty. Hot2cold did install this four years ago with the previous landlord.

Customer called us out to get a quote on a new compressor for the unit he has. Customer has a 2 ton Goodman heat pump. Customer had another company come out to diagnose the issue and Troy corroborated the diagnosis of needing a new compressor. As to the cause of why the compressor seized it looks that the fins on the edge of the Compression unit are clogged up and there’s a lot of foliage on one side, which is restricting airflow coming into cool off the compression bulb. Customer is looking to get one more house to come out and give them a quote on the compressor. Quoted customer on a warranty 2 ton compression bulb as he is still under the Goodman warranty, but he is outside of the gap warranty. Hot2cold did install this four years ago with the previous landlord.

Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Changed the filter for the customer

Changed the filter for the customer

Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Customers with compressor was off-line due to a bad float switch. We jumped out the float switch. I got everything turned back on.

Customers with compressor was off-line due to a bad float switch. We jumped out the float switch. I got everything turned back on.

Corey B.

Corey B. Job Checkin

Performed yearly maintenance

Performed yearly maintenance

Corey B.

Corey B. Job Checkin

Provided estimates for cuztomer

Provided estimates for cuztomer

James T.

James T. Job Checkin

Today we visited to perform a maintenance on the air conditioning system. The unit is from 2006, but in working order. The refrigerant pressures are where they should be, the temperature differential is spot on and the unit keeps working.

Today we visited to perform a maintenance on the air conditioning system. The unit is from 2006, but in working order. The refrigerant pressures are where they should be, the temperature differential is spot on and the unit keeps working.

James T.

James T. Job Checkin

Inverter technology delivers the most efficient and comfortable home available. This machine is like having dozens differently sized AC units! It utilizes a variable speed compressor, variable speed outdoor fan, and variable speed indoor blower to continuously throttle the exact amount of cooling power required. The unit monitors outdoor temperature, indoor temperature, and the desired temperature while using a learning algorithm to deliver peak efficiency and humidity control.

Inverter technology delivers the most efficient and comfortable home available. This machine is like having dozens differently sized AC units! It utilizes a variable speed compressor, variable speed outdoor fan, and variable speed indoor blower to continuously throttle the exact amount of cooling power required. The unit monitors outdoor temperature, indoor temperature, and the desired temperature while using a learning algorithm to deliver peak efficiency and humidity control.

Corey B.

Corey B. Job Checkin

Filter 16x20x5

Filter 16x20x5

Corey B.

Corey B. Job Checkin

Preventive maintenance complete. Self rinse evaporate coil and wash condenser coil, shop vacuum drain line. All electrical components working normal.

Preventive maintenance complete. Self rinse evaporate coil and wash condenser coil, shop vacuum drain line. All electrical components working normal.

James T.

James T. Job Checkin

Complete installation of a new 2-ton air conditioning system and installing one new supply vent in the laundry room.

Complete installation of a new 2-ton air conditioning system and installing one new supply vent in the laundry room.

James T.

James T. Job Checkin

Today we visited to get the materials and invoice together for an upcoming installation.

Today we visited to get the materials and invoice together for an upcoming installation.

James T.

James T. Job Checkin

Today we visited to provide a second opinion regarding the AC unit. Mr. Mindykowski had another AC company perform a system maintenance and when they completed the maintenance they charged him $488 even though the maintenance was supposed to cost $150. After evaluating the system the unit is past its expected useful life, but it is working fine.


James T.

James T. Job Checkin

1200 CFM ductwork and new blower motor

1200 CFM ductwork and new blower motor

James T.

James T. Job Checkin

Today we visited to evaluate the ductwork and determine why the blower failed prematurely. We learned the ductwork is not compatible with the modern AC unit. We will be returning to replace the ductwork and replace the faulty blower motor.

Today we visited to evaluate the ductwork and determine why the blower failed prematurely. 

We learned the ductwork is not compatible with the modern AC unit. We will be returning to replace the ductwork and replace the faulty blower motor.

Brennan  G.

Brennan G. Job Checkin

Included in the replacement quote are the following 10 Year Parts Warranty 1 Year Labor Warranty 1 Year Maintenance club ( 1 free maintenance within the first year of installation) All required permits and inspections 5kw Heat kit (electric heaters) New air handler stand , emergency pan and float switch. New drain pump Required breaker changes New condenser pad and straps Chemical flush of the lineset New supply duct plenum New thermostat (Honeywell T6 pro) Removal and disposal of old equipment Duct sanitation Post installation start up and checks $500 Incentive Discount Financing not available for this price 50% deposit required before 05/05/22

Included in the replacement quote are the following
10 Year Parts Warranty 
1 Year Labor Warranty 
1 Year Maintenance club ( 1 free maintenance within the first year of installation)
All required permits and inspections 
5kw Heat kit (electric heaters)
New air handler stand , emergency pan and float switch.
New drain pump 
Required breaker changes 
New condenser pad and straps
Chemical flush of the lineset 
New supply duct plenum 
New thermostat (Honeywell T6 pro)
Removal and disposal of old equipment 
Duct sanitation 
Post installation start up and checks 
$500 Incentive Discount 
Financing not available for this price