1503 U.S. 301
Tampa, FL 33619
813-580-8800

Local Reviews
for pinellas park, fl

Rated 4.7 out of 5 stars based on 6 customer reviews

Excellent service

James is great!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Courteous and honest

  • Overall Experience
  • Quality
  • Price
  • Convenience

Compressor Plate

Just found the metal plate that am guessing goes over the compressor, leaning against house. Not good. Was not informed of what needed to be done beforehand. Did not receive an invoice for said work done, although I did call and woman who answered emailed it out right away, very appreciated. Did very good job on drain pipe, not sure if inside unit was opened to fix clog.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service awesome tech

Awesome experience

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pinellas park, fl

James T.

James T. Job Checkin

Inverter technology delivers the most efficient and comfortable home available. This machine is like having dozens differently sized AC units! It utilizes a variable speed compressor, variable speed outdoor fan, and variable speed indoor blower to continuously throttle the exact amount of cooling power required. The unit monitors outdoor temperature, indoor temperature, and the desired temperature while using a learning algorithm to deliver peak efficiency and humidity control.

Inverter technology delivers the most efficient and comfortable home available. This machine is like having dozens differently sized AC units! It utilizes a variable speed compressor, variable speed outdoor fan, and variable speed indoor blower to continuously throttle the exact amount of cooling power required. The unit monitors outdoor temperature, indoor temperature, and the desired temperature while using a learning algorithm to deliver peak efficiency and humidity control.

Corey B.

Corey B. Job Checkin

Filter 16x20x5

Filter 16x20x5

Corey B.

Corey B. Job Checkin

Preventive maintenance complete. Self rinse evaporate coil and wash condenser coil, shop vacuum drain line. All electrical components working normal.

Preventive maintenance complete. Self rinse evaporate coil and wash condenser coil, shop vacuum drain line. All electrical components working normal.

James T.

James T. Job Checkin

Complete installation of a new 2-ton air conditioning system and installing one new supply vent in the laundry room.

Complete installation of a new 2-ton air conditioning system and installing one new supply vent in the laundry room.

James T.

James T. Job Checkin

Today we visited to get the materials and invoice together for an upcoming installation.

Today we visited to get the materials and invoice together for an upcoming installation.

James T.

James T. Job Checkin

Today we visited to provide a second opinion regarding the AC unit. Mr. Mindykowski had another AC company perform a system maintenance and when they completed the maintenance they charged him $488 even though the maintenance was supposed to cost $150. After evaluating the system the unit is past its expected useful life, but it is working fine.


James T.

James T. Job Checkin

1200 CFM ductwork and new blower motor

1200 CFM ductwork and new blower motor

James T.

James T. Job Checkin

Today we visited to evaluate the ductwork and determine why the blower failed prematurely. We learned the ductwork is not compatible with the modern AC unit. We will be returning to replace the ductwork and replace the faulty blower motor.

Today we visited to evaluate the ductwork and determine why the blower failed prematurely. 

We learned the ductwork is not compatible with the modern AC unit. We will be returning to replace the ductwork and replace the faulty blower motor.

Brennan  G.

Brennan G. Job Checkin

Included in the replacement quote are the following 10 Year Parts Warranty 1 Year Labor Warranty 1 Year Maintenance club ( 1 free maintenance within the first year of installation) All required permits and inspections 5kw Heat kit (electric heaters) New air handler stand , emergency pan and float switch. New drain pump Required breaker changes New condenser pad and straps Chemical flush of the lineset New supply duct plenum New thermostat (Honeywell T6 pro) Removal and disposal of old equipment Duct sanitation Post installation start up and checks $500 Incentive Discount Financing not available for this price 50% deposit required before 05/05/22

Included in the replacement quote are the following
10 Year Parts Warranty 
1 Year Labor Warranty 
1 Year Maintenance club ( 1 free maintenance within the first year of installation)
All required permits and inspections 
5kw Heat kit (electric heaters)
New air handler stand , emergency pan and float switch.
New drain pump 
Required breaker changes 
New condenser pad and straps
Chemical flush of the lineset 
New supply duct plenum 
New thermostat (Honeywell T6 pro)
Removal and disposal of old equipment 
Duct sanitation 
Post installation start up and checks 
$500 Incentive Discount 
Financing not available for this price
50% deposit required before 05/05/22

Geraldo R.

Geraldo R. Job Checkin

Replaced air handler breaker. Relocated disconnect for air handler. Number ten wire going to air handler. Adjusted refrigerant charge.

Replaced air handler breaker. Relocated disconnect for air handler. Number ten wire going to air handler. Adjusted refrigerant charge.

Brennan  G.

Brennan G. Job Checkin

Brennan G Todays visit was for the system not cooling. Preformed inspection and diagnosis and found the thermostat had failed and the outside capacitor was very weak. Replaced both components to get the system up and running. Vacuumed the drain as a courtesy, it backed up while onsite. The current system is out of manufacture warranty and is only a 13 SEER. Also the equipment has multiple concerns regarding cleanliness and reliability. I suggested the equipment be replaced vs repaired. Gave john a replacement estimate. He plans to get other quotes. System is cooling at this time. Service call Replace thermostat (basic Thermostat) Replace compressor fan dual capacitor

Brennan G
Todays visit was for the system not cooling.
Preformed inspection and diagnosis and found the thermostat had failed and the outside capacitor was very weak.
Replaced both components to get the system up and running.
Vacuumed the drain as a courtesy, it backed up while onsite.
The current system is out of manufacture warranty and is only a 13 SEER.
Also the equipment has multiple concerns regarding cleanliness and reliability.
I suggested the equipment be replaced vs repaired.
Gave john a replacement estimate. He plans to get other quotes. 
System is cooling at this time.
Service call 
Replace thermostat (basic Thermostat)
Replace compressor fan dual capacitor

Geraldo R.

Geraldo R. Job Checkin

Replaced 45/5 uf run capacitor refrigerant levels are good

Replaced 45/5 uf run capacitor refrigerant levels are good

Brennan  G.

Brennan G. Job Checkin

Brennan G Todays Visit was for a system replacement estimate I Emailed Brett estimates for the replacement of the ac system. Brett told me he will follow up next week.

Brennan G
Todays Visit was for a system replacement estimate 
I Emailed Brett estimates for the replacement of the ac system.
Brett told me he will follow up next week.

James T.

James T. Job Checkin

A two-stage unit is like having two AC units in one, a large system for the hot hours of the day and a smaller unit for the rest of the time. This unit “shifts” between high and low to deliver high efficiency and even temperatures.

A two-stage unit is like having two AC units in one, a large system for the hot hours of the day and a smaller unit for the rest of the time. This unit “shifts” between high and low to deliver high efficiency and even temperatures.

James T.

James T. Job Checkin

Today we visited to evaluate the air conditioning system. Ashley was not sure if the system needed service or replaced. We learned the unit needed replaced so we will be returning on Friday to install a new two-stage system.

Today we visited to evaluate the air conditioning system. Ashley was not sure if the system needed service or replaced. We learned the unit needed replaced so we will be returning on Friday to install a new two-stage system.