1503 U.S. 301
Tampa, FL 33619
813-580-8800

Local Reviews
for apollo beach, fl

Rated 4.7 out of 5 stars based on 26 customer reviews

Outstanding service!

Le is fantastic! Very professional, knowledgeable, and took the time to explain what he was doing and answered all of my questions. Highly recommend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellence service

We received excellent service from Troy.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Superb Service, Great Price

Jeanette did a great job getting us set up with the service call and keeping us informed every step of the way. Troy was extremely knowledgeable, professional and thorough while servicing the HVAC. He provided valuable information and tips for keeping it running smoothly. Fantastic customer service throughout - HIGHLY RECOMMEND!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service at a Great Price!

My HIGHEST recommendation! Jeanette (office manager) provided excellent customer service and scheduled us for same day service. Le and Louis (AC service technicians) were phenomenal…knowledgeable, professional, and genuinely took pride in their work. These three individuals were superb, and we will be using Hot2Cold for all of our AC service needs. Thank you!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great support and services all around.

When my A/c broke I called 8 companies. Hot 2 Cold was the 6th I called, the second to show up for an assessment (on a Sunday) They were 1/8 who offered portable air conditioners to help with the situation and reduce the urgency so we could make a sound choice. The techs came within 2 days and quickly and efficiently installed a whole ne system. Their detail was incredible all the piping and wiring is clean and neat. Much appreciated when one loses the A/c in the Florida summer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Customer service was excellent! Corey delivered and explained lot of things about our system that we did not know. Gave us peace of mind about future system requirements. I highly recommend him and this company. I believe them to be honest, on time and nice people.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service from start to finish

First time using Hot 2 Cold and I was very happy with the service. The company representatives are professional and courteous. I have no complaints. Troy came out to my house , serviced my ac, answered all my questions and was very patient and personable. He never made me feel like he was in a rush. Thank You! I will tell my neighbors and friends about you guys❤️

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Your technician was super and very helpful I am still waiting for quotes Pl send

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Excellent customer service and very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

I'll use them again

Brennan is super. He was very professional and responsive. He was also extremely knowledgeable and was able to explain all the details--including the additional ones I asked about. I will definitely use Hot2Cold in the future.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Great service. Very thorough and kept me informed as he saw things. I highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

Tony was very helpful and kind.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Unhappy

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for apollo beach, fl

Corey B.

Corey B. Job Checkin

Upon arrival found unit low on refrigerant. Leak search and found a minor leak in evaporator coil. (Video included) As off right now the unit is cooling but as the ambient temperature rises outside you will lose cooling efficiency as the temperature of refrigerant increases. Evaporator coil needs to be replaced

Upon arrival found unit low on refrigerant.
Leak search and found a minor leak in evaporator coil. (Video included)
As off right now the unit is cooling but as the ambient temperature rises outside you will lose cooling efficiency as the temperature of refrigerant increases. 
Evaporator coil needs to be replaced

David M.

David M. Job Checkin

Upon arrival compressor was not running. I opened outside unit and found capacitor wires completely fried. I repaired wires and compressor turned right on. I also checked and made sure capacitor was still good. Once system kicked on I checked pressures and system was low on 410a. The suction line was starting to freeze up. I informed customer and added 2 pounds of refrigerant. Customer also wants a quote for a new mini split. Customer paid $300 with check. #9636.

Upon arrival compressor was not running. I opened outside unit and found capacitor wires completely fried. I repaired wires and compressor turned right on. I also checked and made sure capacitor was still good. Once system kicked on I checked pressures and system was low on 410a. The suction line was starting to freeze up. I informed customer and added 2 pounds of refrigerant. Customer also wants a quote for a new mini split. Customer paid $300 with check. #9636.

Corey B.

Corey B. Job Checkin

Customer called us out because the compressor was going off at night. Upon investigation, Troy found that the ambient sensor was getting tripped at the cooler temperature. Went ahead and jumped out the low pressure switch, which was attached to the ambient pressure switch and got the machine up and running if there are more problems, the board was acting a little strange Might be worth looking into replacing the board at some point.

Customer called us out because the compressor was going off at night. Upon investigation, Troy found that the ambient sensor was getting tripped at the cooler temperature. Went ahead and jumped out the low pressure switch, which was attached to the ambient pressure switch and got the machine up and running if there are more problems, the board was acting a little strange Might be worth looking into replacing the board at some point.

David M.

David M. Job Checkin

Replaced condenser fan motor. Inspected old motor and found the shaft was loose and the fan was running backwards. Also amps were very high and motor was not working properly. Replaced motor and system is running correctly. Checked amps and amps are good. Checked pressures .

Replaced condenser fan motor. Inspected old motor and found the shaft was loose and the fan was running backwards. Also amps were very high and motor was not working properly. Replaced motor and system is running correctly. Checked amps and amps are good. Checked pressures .

Corey B.

Corey B. Job Checkin

Customer called us out because her system was not working. Upon investigation Troy found that we had installed a motor on her condenser that was an aftermarket and has failed within the year so we need to replace the condenser fan motor. I have already replaced the capacitor, but we will need to schedule a return visit to replace the condenser fan motor.

Customer called us out because her system was not working. Upon investigation Troy found that we had installed a motor on her condenser that was an aftermarket and has failed within the year so we need to replace the condenser fan motor. I have already replaced the capacitor, but we will need to schedule a return visit to replace the condenser fan motor.

Corey B.

Corey B. Job Checkin

Customer called us out because thermostat wasn’t reading correctly. Customer was low on Freon and we added to adjust.

Customer called us out because thermostat wasn’t reading correctly. Customer was low on Freon and we added to adjust.

rodney@hot2coldairconditioning.com

rodney@hot2coldairconditioning.com Job Checkin

Upon arrival I leak tested system after finding it low on refrigerant Found leak located on top layer of evaporator coil Provide estimate for replacement and emailed landlord

Upon arrival I leak tested system after finding it low on refrigerant
Found leak located on top layer of evaporator coil
Provide estimate for replacement and emailed landlord

Corey B.

Corey B. Job Checkin

Zone board replacement. Current zone board is not receiving the 24 V crossing from the thermostats to the equipment. We measured the 24 V going from thermostat into the zone board unsuccessfully on both thermostats and then saw 24 V coming back from the equipment side, so the signal is getting lost in the board for the equipment to shut off. Replace float switch and cup, there is currently no cup for the float

Zone board replacement. Current zone board is not receiving the 24 V crossing from the thermostats to the equipment. We measured the 24 V going from thermostat into the zone board unsuccessfully on both thermostats and then saw 24 V coming back from the equipment side, so the signal is getting lost in the board for the equipment to shut off.

Replace float switch and cup, there is currently no cup for the float

Corey B.

Corey B. Job Checkin

Sulfate had fallen out durning hurricane cause a lot of insulation to be covered unit maintenance was needed Inside a/h had rust build up on stricker because of razor blade that was sitting on top of unit told. Customer of concern Check of amps and made sure to sticker tag are on both units Drain line cleaning was done as well Made sure unit kick on and compressor was flowing b4 leaving

Sulfate had fallen out durning hurricane cause a lot of insulation to be covered unit maintenance was needed
Inside a/h had rust build up on stricker because of razor blade that was sitting on top of unit told. Customer of concern
Check of amps and made sure to sticker tag are on both units
Drain line cleaning was done as well
Made sure unit kick on and compressor was flowing b4 leaving

Corey B.

Corey B. Job Checkin

Customer had us out again because the compressor would not turn off after it had achieved its temperature. Upon investigation, Troy found that the zone board that was in place is faulty. We determine this by measuring the 24 V between the common and yellow wire on the thermostat side of the zone board for the top thermostat in the bottom thermostat and we’re not getting 24 V. On the other side of the board where the equipment is, we were getting 24 V coming from the equipment side so that indicated the failure was inside of the zone board. Technician visited with tenants and sent the estimate to the owners. Spoke with the owners and they are just deciding whether or not they would like to also replace the float switch or not.

Customer had us out again because the compressor would not turn off after it had achieved its temperature. Upon investigation, Troy found that the zone board that was in place is faulty. We determine this by measuring the 24 V between the common and yellow wire on the thermostat side of the zone board for the top thermostat in the bottom thermostat and we’re not getting 24 V. On the other side of the board where the equipment is, we were getting 24 V coming from the equipment side so that indicated the failure was inside of the zone board. Technician visited with tenants and sent the estimate to the owners. Spoke with the owners and they are just deciding whether or not they would like to also replace the float switch or not.

Corey B.

Corey B. Job Checkin

Customer was complaining that the system was not keeping up in the upstairs more than the downstairs. Upon investigation, Troy found that it was controlled by a zone board. Troy also discovered that the upstairs thermostat was low on batteries and not admitting enough 24 V to the equipment, which wasn’t allowing the airflow to happen. We charge the system up with some more refrigerant and we replace the batteries And everything seems to be running smoothly.

Customer was complaining that the system was not keeping up in the upstairs more than the downstairs. Upon investigation, Troy found that it was controlled by a zone board. Troy also discovered that the upstairs thermostat was low on batteries and not admitting enough 24 V to the equipment, which wasn’t allowing the airflow to happen. We charge the system up with some more refrigerant and we replace the batteries And everything seems to be running smoothly.

rodney@hot2coldairconditioning.com

rodney@hot2coldairconditioning.com Job Checkin

This estimate is being presented for the replacement of the Blower Motor that is under Warranty

This estimate is being presented for the replacement of the Blower Motor that is under Warranty

Corey B.

Corey B. Job Checkin

4T heat pump

4T heat pump

Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Customer had to sell because his mini split was not cooling properly. Upon investigation, Troy found that there was very little pressure and it was very low on Freon. Added 1 pound of Freon to the system and got a 18° temperature split.


Skof135@yahoo.com

Skof135@yahoo.com Job Checkin

Customer called us out to quote him on system replacement. We provided estimates for him both with ductwork and without. Customer prefers to stay on train. Customer is not a fan of Lennox Goodman or Grande air