Performed yearly maintenance
I quoted them on replacing machines
Customer heat strip has melted. The wires system will require a new heat strip for heat to work. Customer will pay when work is completed.
Today we visited to provide pricing to replace the air conditioning system. The current unit is from 2002, uses R-22 refrigerant, and has a refrigerant leak somewhere. Instead of replacing parts Kevin will replace the system. James gathered the necessary information to offer pricing to replace the equipment. After the heat load is finished to confirm equipment tonnage James will be sending the quote. Kevin is interested in Carrier brands (Carrier, Bryant, Comfortmaker, Payne), Lennox brands (Lennox and Allied), and York brands (York and Champion).
Today we visited for the annual maintenance on the air conditioning system.
Replacement/Redesign of the air delivery system and cleaning and reconditioning of the the air conditioning system.
This appointment was for James to complete design.
1 year warranty on the new motor New capacitor for the motor Also bring dual tube uv lamp Repair Option removed old motor and left with homeowner installed 1/2hp blower motor system up and running
Brennan G Todays visit was too diagnose the blower motor Found a new blower motor was installed by another company , the motor is the incorrect voltage and horsepower for the system. Wired motor so that it would run and provide cooling for the home until we return with the correct motor. We also need to return with a new uv lamp that our installers broke while onsite. Repair is scheduled for Tuesday. Quoted $425 for the new motor installed Includes a new capacitor and the repair will have a 1 year warranty. No charge for todays visit , courtesy follow up , gave Gabriel $400 off the motor as a thank you for choosing us to do business with. The new motor will need to be a 240v 1/2 HP according the air handler data plate
1400 CFM air delivery system and relocation of the air handler Brennan G todays visit was to diagnose the blower motor and test system Found bad capacitor, replaced capacitor as a courtesy and tested system Set blower to medium high speed , total static is at .40 System cooling with 20* temp split Refrigerant charge is good 10* superheat Washed the outside coil
Today we visited to provide pricing to replace/redesign the air duct system. Gabriel chose to go ahead and hire Hot 2 Cold for his project.
Completed, Found system low on refrigerant, gave estimate for new evaporator coil, Collected service call $79.00
Repair Option, completed Removed clogged filter adjusted sub cooling,and installed hard start kit, temperatures and pressures checked good and draining properly.