Geraldo R.

Geraldo R. Job Checkin

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System.


Geraldo R.

Geraldo R. Job Checkin

1 Time Maintenance

1 Time Maintenance

Geraldo R.

Geraldo R. Job Checkin

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Fixed connection to Tstat. AA lithium batteries to outdoor sensors need to be replaced

Perform diagnostic and evaluation of System operation and present Customer with multiple options for Maintenance, Repair, or Replacement of System. Fixed connection to Tstat. AA lithium batteries to outdoor sensors need to be replaced

Corey B.

Corey B. Job Checkin

The Bosch IDS Light is the first 15-SEER Inverter condenser on the market. This BOVA15 outdoor system combines the standard efficiency with our BVA15 fixed-speed air handler. With IDS Light, you get the benefits of our inverter system at a price point you’ll love!

The Bosch IDS Light is the first 15-SEER Inverter condenser on the market. This BOVA15 outdoor system combines the standard efficiency with our BVA15 fixed-speed air handler. With IDS Light, you get the benefits of our inverter system at a price point you’ll love!

James T.

James T. Job Checkin

Today we visited to determine the best solution in regards to installing the new air conditioning system. The current air handler is in a tight space with plumbing and trusses preventing easy removal. We learned the best method to replace the air handler will be to remove the system through the return box opening we will be returning tomorrow to install the new equipment.

Today we visited to determine the best solution in regards to installing the new air conditioning system. The current air handler is in a tight space with plumbing and trusses preventing easy removal.

We learned the best method to replace the air handler will be to remove the system through the return box opening we will be returning tomorrow to install the new equipment.

James T.

James T. Job Checkin

Today I visited to determine why the upstairs playroom and hallway felt warm and humid. I found one of the panels was left off of the air handler and the unit was pulling in air from the attic. This is resolved. The AC that cools this portion of the home is a 4-ton Carrier unit from 2019. While investigating the humidity problem I learned there is a mold/mildew problem in the ductwork. Replacing all of the ductwork would be an expensive and burdensome project. The simplest solution will be to install a whole home air/surface purification system in each air handler. This device works to eliminate mold, viruses, bacteria, odors, and VOCs from all of the air and very hard surface. Installing this costs $1,506 per unit. I’m aware of four systems in the home.

Today I visited to determine why the upstairs playroom and hallway felt warm and humid. I found one of the panels was left off of the air handler and the unit was pulling in air from the attic. This is resolved. The AC that cools this portion of the home is a 4-ton Carrier unit from 2019.

While investigating the humidity problem I learned there is a mold/mildew problem in the ductwork. Replacing all of the ductwork would be an expensive and burdensome project. The simplest solution will be to install a whole home air/surface purification system in each air handler. This device works to eliminate mold, viruses, bacteria, odors, and VOCs from all of the air and very hard surface. Installing this costs $1,506 per unit. I’m aware of four systems in the home.

James T.

James T. Job Checkin

Today we visited to determine why the garage AC unit is not working. We learned the system has a failed control board. The faulty board prevented us from evaluating the function of the compressor and refrigerant system. The control board is available but too expensive for an old unit. The system was discontinued in 2012. James completed a heat load and provided Korby, Tug, and Brenda with the relevant replacement information.

Today we visited to determine why the garage AC unit is not working. We learned the system has a failed control board. The faulty board prevented us from evaluating the function of the compressor and refrigerant system. 

The control board is available but too expensive for an old unit. The system was discontinued in 2012. 

James completed a heat load and provided Korby, Tug, and Brenda with the relevant replacement information.

James T.

James T. Job Checkin

Today we visited to provide pricing to repair the outside unit. We were unable to gain access to the inside unit today. The outside unit was crushed from the falling branch. The metal jacket, condensing coil, lid, fan blades, fan shroud, and fan motor were damaged. Replacement of the parts would cost more than an outside unit.

Today we visited to provide pricing to repair the outside unit. We were unable to gain access to the inside unit today.

The outside unit was crushed from the falling branch. The metal jacket, condensing coil, lid, fan blades, fan shroud, and fan motor were damaged.  Replacement of the parts would cost more than an outside unit.

Hector O.

Hector O. Job Checkin

Found system low on 410A Owner opted to top unit off with 410A Left options in the event owner decides to upgrade Did not perform leak search by homeowners request 410A

Found system low on 410A 
Owner opted to top unit off with 410A
Left options in the event owner decides to upgrade 
Did not perform leak search by homeowners request
410A

Corey B.

Corey B. Job Checkin

Maintenance washed condenser, cleaned coil, shop vacuum drain line. Unit working correctly

Maintenance washed condenser, cleaned coil, shop vacuum drain line. Unit working correctly

Geraldo R.

Geraldo R. Job Checkin

Changeout EEV motor plus preventative maintenance on four systems. Cleaned all evaporator coils with self rinse cleaner and added drain clear concentrate to all drain lines. Sanitized ducts. Cleaned condenser coils and checked refrigerant levels along with subcool (10)and superheat (10-15)temperatures. Amp draws on fan motors and compressors are in range.v

Changeout EEV motor plus preventative maintenance on four systems. Cleaned all evaporator coils with self rinse cleaner and added drain clear concentrate to all drain lines. Sanitized ducts. Cleaned condenser coils and checked refrigerant levels along with subcool (10)and superheat (10-15)temperatures. Amp draws on fan motors and compressors are in range.v

Geraldo R.

Geraldo R. Job Checkin

Found bad EEV motor in air handler

Found bad EEV motor in air handler