Ductwork inspection. New customer with 1400 square-foot home. Spoke with homeowner, and they had some shower remodel working done in the master bathroom and the pipes had broken underneath the slab. Home has floor supply ducts and is a downflow system. The downflow Supply ducks are currently filled with water 6 inch supply in front entry is filled 5 inches with water. inspected other ducks and they also have water. Checked the supply Plenum from the ‘A’ plate and the evaporator coil and it has about 3 inches of standing water in it. Went over options for shop, backing and removing water with video inspection camera versus having a plumber come and do a leak detection. Homeowner decided to go ahead and have a shop vac today to see if there’s an active leak in the Ductwork. Spent two hours and removed 296+ gallons of water, dirt, sand, and debris from Ductwork. Used inspection camera to ensure that we had removed as much water in the ductwork as possible. Went to the lowest points incl