Blue shield plan, summer AC service in RUUD 2007 Air Conditioner and split system. Spoke with customer and they were still interested in getting more airflow to south west corner baby’s room. It is a along run, over 35 feet, and I had left a previous estimate to increase returns and add dampers. Today I will leave an estimate to increase return size only and increase duct to baby’s room only. Inspected filters and they looked fresh, so I left the extra filters included with todays Service. Checked thermostat controls, went in attic and checked evaporator coil, drain line and flushed out drain line with water. Checked blower, blower capacitor and drain pan. Checked ductwork and went outside. Washed condenser thoroughly from built up dog hair and dirt from past season. Cleaned contactor, capacitor connection points and access panel from excess debris. Checked dual capacitor. Cycled system on and checked fan amps, compressor, refrigerant charge and outside temperature split. System is r