9320 S. Pole Rd
Oklahoma City, OK 73160
(405) 794-8900

Our Top Cities


Job Locations
for the village, ok


Map of The Village OK
ISAAC J.

ISAAC J.


Job Checkin

Came out to call for a system not cooling properly. Customer stated that the AC system wasn’t operating properly, and the fan on the outside unit wasn’t spinning. I checked the system over and found the capacitor depleted and the start wire to compressor burned. Discussed with customer about repair needed and fixing wire. Customer approved repair needed. I replaced the capacitor and fixed minor burned wire. Washed condenser coil and cycled system back on. Checked amps, temperatures and pressures of Condenser. System was running just out of range according to my temperatures and pressures. Discussed with customer about leak search and system needing refrigerant. Customer wanted to add refrigerant for now and do a leak search the next AC visit they have to see if we can find a leak. I added 1.2lbs of 410a to system to get unit within proper range. System is now cooling properly.