9320 S. Pole Rd
Oklahoma City, OK 73160
(405) 794-8900

Our Top Cities


Job Locations
for the village, ok


Map of The Village OK
ISAAC J.

ISAAC J.


Job Checkin

Came out to call for a system making noise and not heating properly. I checked he system over and found the noise was the inducer motor bearings weakened causing vibrations. The reason the furnace wouldn’t work was actually the ignitor not getting hot enough to ignite the gas. Checked voltage and had proper voltage to the ignitor, so the ignitor is bad. Discussed with customer about repair needed to get system operational and the repair I recommend getting done as well. Customer approved replacement of the ignitor to get system operational and would like me to look into pricing and availability of inducers motor. I replaced the ignitor, cleaned the flame sensor and checked operation of furnace. System is now heating properly.