23OCT2023 Jason Brown Arrived for 2 yo no cool. Spoke with homeowner about the systems performance. The outside unit is running but we noticed it freezing and the blower motor isn’t running. Inspected furnace. Checked amps and voltage to fan. Cycled equipment in fan only motor tries to start then drops out. Verified high voltage and control voltage. Checked for power from board. Fan motor has failed. Called Carrier for availability. The Motor is available and repairs scheduled for tomorrow from 3-5 pm 24OCT2023 Jason Brown Arrived for previously discussed motor replacement. Removed existing motor. Install new motor. While installing the motor I found chunks of old insulation that has come off the old return plenum ( metal box) inside the blower wheel. Removed debris and verified wheel was not damaged. Cycled equipment in heating and tested amps and airflow. Manually kicked AC on at board to verify communication. System is working properly at this time.