Installation of new devices throughout the home including one dimmer on the first floor controlling a foyer fixture, duplex’s in multiple areas (either broken or plugs falling out), box repair and device change for fridge, and two others. We will also replace the current vanity fixtures in both bathrooms on the second floor as well as adding a new exhaust fan located in the hall bath. Install new two gang switch located outside the bathroom to control a wall sconce outside of the bedrooms. Per inspection sheet recommending checking on grounding, we recommended a new whole home surge protector as well as changing shared neutral circuits with common handle breakers and separating grounds and neutrals. Returned today to complete WPQ. We removed the mirrors in the primary and hallway 2nd floor bathrooms and removed the light fixtures. We discovered that none of the fixtures had boxes to support the new fixtures, so we installed new 8B boxes. We removed the old bath fan in the hallway bat