Reason for today’s visit was to look at some safety concerns from the customer as well as the home inspector. First inspected the main panel and found that it was an older bryant 125 amp panel that was just about full. There was no grounding in the home and the service cable was beginning to dry rot. We also found that there were still a few of the original switches from another was built. When customer took us out back, we found that one of the receptacles was tapped out of the line side of the air conditioning disconnect. We also seen that a pipe with a light hanging off of it, was fairly secure to the Home. Customer also made a request to have A new 30 amp 240 V dryer circuit ran from the main panel over to the washroom for a new electric dryer. A few of the other safety concerns we found were wires dangling in the unfinished area where the sump pump was located. He also recommended installing a GFCI with an audible alarm for the sump pump. Some of the final tasks included, hiding