Pump down refrigerant removed coil replaced coil and TXV. Added to metal strips on both sides of the coil to prevent any water from splashing out as the drain pan of the new coil was very shallow on the outside edge. Pulled the vacuum the 300 µm. Released refrigerant check charge. Charge system to manufacturer specs.