Job Checkin

Found crawlspace has more than enough combustion air for furnace. Crawlspace comes in around 3780 cubic feet. Required combustion air for furnace comes in around 2000 cubic feet. See attached form for more details, crawlspace has enough air to supply for a 75,000 btu furnace. System is only 40,000 btus.