253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Job Locations
for fletcher, nc


Map of Fletcher NC
Cameron  S.

Cameron S.


Job Checkin

Returned 7/24 10 days after 7/14 service call for not enough cooling - found system beginning to ice up - defrosted system and checked system refrigerant balance, system refrigerant levels returned to same refrigerant levels from 7/14 indicating a significant refrigerant leak has occurred - found evidence of refrigerant oil on outdoor condenser coil - noticed apparent coil damage on upper right hand side of coil to right of electrical panel - confirmed leak with electronic leak detector - recommend replacement of condenser coil or replacement of condenser. Scheduled estimate to replace condenser coil 7/30/25 around 11 am