Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **GARAGE ATTIC INDOOR (Air Handler - West Side):** * Verified the unit is in good condition. * Confirmed filter size is 20x20x4. * The existing pleated 2-6" filter was checked. * Customer will provide their own replacement filters. * Confirmed indoor coil is clean and in good condition. * Tested and inspected electrical components: * Blower motor * Blower run capacitor * Electrical wiring * Inspected components: * Blower wheel * Secondary drain pan * Primary drain pan * Electrical wires secured * Ductwork * Measured: * Return air temperature: 75.0 Degrees Fahrenheit * Supply air temperature: 59.0 Degrees Fahrenheit * Addressed condensate drain system: * Cleared drain line * Cleaned out primary pan * Cleaned out secondary pan * Tested safety switch **GARAGE ATTIC OUTDOOR (Heat Pump - Side