Job Checkin

Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: Good Indoor Unit: Location: Garage Type: Furnace Area Unit Services: Whole house Filtration: Pleated 1" filter Replaced today Filter size: 20x20 Indoor Coil: Good condition Outdoor Unit: Location: Side of house Type: Straight Cool Condition of outdoor coil: Good Tested and inspected electrical components: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Contactor Electrical Wiring Fan Run Capacitor Compressor Start Capacitor Inspected components in good condition: Blower Wheel Primary Drain Pan Electrical Wires Secured Tested and cleared condensate drain system: Cleared drain line Cleaned out primary pan Tested safety switch Other actions taken: Wore shoe covers Restored power to the units Temperature readings: Return Air Temperature: 74.0°F Supply Air Temperature: 50.0°F Technician Recommendations: N/A Te