Today I arrived on site and performed a summer tune-up on the system. Here's a summary of the work completed: **Filtration:** * Replaced the Respicare filter with a spare provided by the customer (16x25 size). **Electrical Components (Tested and Working):** * Verified proper operation and amperage within manufacturer specifications for: * Blower Motor * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Electrical Wiring **Component Inspection (Good Condition):** * Confirmed the following components are in good working order: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires Secured **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary and secondary drain pans. * Tested the safety switch. **Other:** * Dusted the thermostat. * Restored pow