Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Furnace in Garage):** * Observed the indoor unit to be in fair condition. * Confirmed the indoor coil was in fair condition and clean. * Noted the filter size as 12x24 and that the customer has spare pleated 1" filters. **Outdoor Unit (Straight Cool on Side of House):** * Observed the outdoor unit to be in fair condition and clean. **Electrical Components:** * Verified proper operation of the inducer draft motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, furnace control board, and electrical wiring. **Component Inspection:** * Confirmed the blower wheel, primary drain pan, electrical wires, and ductwork are in good condition and working properly. **System Testing & Adjustments:** * Measured a return air temperature of 70.0°F and a supply air temperature of 52.0°F. * Cleared the condensate dr