Excellent Ttech and has all the customer service attributions an employer could hope for...
Andrew was very professional and helpful. He did a wonderful job.
Response from Edison Heating & Cooling:
Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.
Both technicians were very nice and explained everything that they were doing.
Quinnton was on time, walked me through what he was doing and got the job done!
Response from Edison Heating & Cooling:
It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.
Andrew was very professional and knowledgeable servicing our AC. His attention to detail was much appreciated , as was his customer service skills. He is an asset to your company
We are always happy with the service we receive. Informative and helpful
Response from Edison Heating & Cooling:
Thank you so much for your 5-star review! We will share this with the team to let them know to keep up the amazing work.
Fantastic, as usual
Response from Edison Heating & Cooling:
Many thanks for taking the time to share your feedback with us. We’re very happy to hear that we met your expectations!
Technician was courteous, professional, and very knowledgeable. Im was impressed..
Tech arrived within the time window I had been provided and worked diligently to resolve my problem of no air conditioning. He was knowledgeable about his work and explained to me what he was doing. He did an excellent job.
Jury arrived earlier than the scheduled time after calling first. His attention to details should be envied by all employers and appreciated by Edison Heating & Cooling. He was polite and presented himself as an experienced technician who also understood customer service. I will always contact your company first whenever the need arises. Thank you, John Hunnewell
Jory was great! He was courteous, friendly and efficient. He answered my questions and did a great job and cleanup.
Performed comprehensive AC maintenance on Carrier 24ABC6 system. Cleaned condenser coils using Nu-Calgon 4291-08 Evap Foam No Rinse. Checked refrigerant charge with Fieldpiece SMAN460 digital manifold, adjusting R-410A levels to manufacturer specifications. Inspected and tightened all electrical connections. Replaced worn contactor with Honeywell DP2030A5004. Lubricated condenser fan motor bearings with Super Lube 21030 synthetic grease. Cleaned evaporator coil and condensate drain line. Replaced air filter with MERV 11 pleated filter. Tested capacitor using Fluke 87V multimeter. Calibrated Ecobee SmartThermostat for optimal performance. System now operating at peak efficiency with 18°F delta T across evaporator coil. Maintenance extends unit lifespan and improves energy efficiency.
Repaired an A/C unit making clicking noises. Diagnosed the issue as a faulty contactor. Disconnected power and replaced the defective contactor with a new one. Inspected and tightened all electrical connections to ensure proper contact. Tested the system for proper operation, confirming the noise was eliminated and the unit was functioning efficiently. Verified the overall performance and reliability of the A/C system.
Diagnosed and repaired Rheem RCFL-HM3617CC air handler. Identified failed ECM blower motor using GE TECMate PRO diagnostic tool. Replaced with OEM UltraTech 51-104305-04 variable-speed motor. Programmed new motor to match system specifications: 1200 CFM, 0.5" ESP. Verified proper communication between thermostat and air handler control board. Tested system operation across all fan speeds. Airflow and energy consumption now within manufacturer parameters.
Finishing up duct repair service today. Identified leaks using smoke pencils and pressure testing. Sealed leaks using UL 181-approved foil tape and mastic sealant to prevent air loss and improve system efficiency. Utilized sheet metal fabrication tools to replace damaged sections of ductwork, ensuring proper airflow distribution. Conducted airflow balancing to optimize performance across all vents. Inspected insulation for damage and replaced as needed to prevent energy loss. Conducted final pressure test to verify integrity of repairs. Documented findings and provided recommendations for further improvements to the duct system.
Executed preventative maintenance on a 4-ton Trane XR16 split system heat pump. Cleaned condenser coils using CalPro foaming coil cleaner. Checked refrigerant charge via superheat and subcooling methods. Replaced air filters. Lubricated motors and pulleys. Tested safety controls and evaluated operating pressures and temperatures.
Completed a thorough AC maintenance service today. Started with cleaning the evaporator and condenser coils to enhance heat exchange efficiency. Checked and topped up the refrigerant levels as per manufacturer specs to ensure optimal cooling. Replaced the air filters with high-efficiency particulate air (HEPA) filters for improved air quality. Inspected all electrical connections and capacitors for safety and functionality. Finished with a system performance test to confirm the unit operates at peak efficiency. Ready for the cooling season!
Conducted annual cooling preventative maintenance service. Checked refrigerant charge levels and added R-410A refrigerant to achieve proper values. Flushed condensate drain line with nitrogen. Cleaned and inspected condenser coil fins, straightening any bent fins. Lubricated motors and checked amp draws. Cycled system through all operating modes to verify proper operation.
Responded to no cooling call. Checked system pressures and temperatures - found undercharged on refrigerant. Performed leak check and repaired aluminum line rubbing on sheet metal. Evacuated system, pulled deep vacuum, and recharged with appropriate R-410A refrigerant charge by weight. Tested operation, made superheat and subcooling adjustments. Unit restored to proper cooling performance.
Andres & Yasser Performed the AC Maintenance
Andres & Yasser Performed the AC maintenance
Andres & Yasser performed the AC Maintenance
During the scheduled maintenance of a Trane XR16 air conditioning unit, a comprehensive examination was conducted, covering all vital components. The refrigerant charge was confirmed to be at the ideal level, the air filters were found to be clean, ensuring efficient airflow, and all electrical connections were secure. The condensate drain was also clear, indicating no obstructions. No issues were identified, affirming the unit's excellent operational condition.