Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2017 Rheem air conditioning system. System is running properly and within manufacture specifications at this time. Advised customer of hard start and surge protection accessories and benefits. I’ll think about adding systems Next year. No further concerns at this time.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a Lennox air conditioner. All electrical and mechanical components of the system checked out at this time. Technician spoke to customer about adding search protector to unit due to recent power outages and power surges in the area. Customer stated he knew the age of the unit and the type of refrigerant it uses and did not want to put another dollar towards the unit and will be buying a new one when this system fails.


Austin L.

Austin L. Job Checkin

Completed annual maintenance on a Lennox air conditioner. All electrical and mechanical components of the system checked out at this time. Technician spoke to customer about adding search protector to unit due to recent power outages and power surges in the area. Customer stated he knew the age of the unit and the type of refrigerant it uses and did not want to put another dollar towards the unit and will be buying a new one when this system fails.


Robby D.

Robby D. Job Checkin

Technicians returned for CFM replacement. Performed repair and cycled system to ensure operation. Unit cycled properly at this time with no concerns.


Austin L.

Austin L. Job Checkin

Conducted annual maintenance on a 2014 Rheem air conditioner. All electrical and mechanical components of the system check out this time.


Robby D.

Robby D. Job Checkin

Called for cooling upon arrival both units cycled on but found compressor not operating. Found voltage distribution system burnt up with wire burnt. Informed customer of fault and tested compressor windings. Ohm readings inconsistent informed customer damage to compressor may be present. 92 Rheem system Presented options hd3 A-E customer chose option a to see if unit will start. Performed repair and cycled unit. System cycled but only ran with 10 degree temperature drop. Found unit low on pressure. Informed customer of options moving forward with 22 system. Customer decided to let unit go due to not knowing if they are moving soon


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2019 Bryant air conditioning system. Unit is running properly and within manufacture specifications at this time. Informed customer of power protection and system enhancement accessories. Customer isn’t interested at this time


Jamie S.

Jamie S. Job Checkin

Gave cost to replace central air conditioning. 60 months 0% financing for installation of air conditioning

Gave cost to replace central air conditioning. 60 months 0% financing for installation of air conditioning

Jamie S.

Jamie S. Job Checkin

Cost to replace air condition. Cost to install high efficiency air condition

Cost to replace air condition. Cost to install high  efficiency air condition

Robby D.

Robby D. Job Checkin

Completion Notes: Upon arrival unit running at 11 degree temp split. Technician preformed pressure test to find correct charge. Technician adjusted airflow into coil to get 18 degree temp split upon departure. No further concerns informed customer it will take a while for temp to go down. If unit still doesn’t seem to be running properly to call us back


Robby D.

Robby D. Job Checkin

Customer stated she didn’t know where filter was located. Showed her how to take door off furnace to access filter. Presented options HH1 to replace filter customer stated she couldn’t afford replacement and she will get a filter herself. No further concerns at this time


Robby D.

Robby D. Job Checkin

Perfomed yearly maintenance and safety checks on 2018 Rheem heat pump system. Unit is running properly and within manufacture specifications at this time. Informed customer of hard start and surge protection accessories customer isn’t interested at this time will consider for fall check.


Jamie S.

Jamie S. Job Checkin

Cost to replace central air condition

Cost to replace central air condition

Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2017 Lennox air conditioning unit. Unit running with 20 degree delta t. Cleaned coil and fan blades. Mechanical checks show a couple signs for concern, first being within the voltage absorption system, reading 42.7/5, manufacture specification rated at 45/5 +/- 5% LRA reading 64. Manufacture specifications rate LRA at 64. Informed customer of concerns and informed customer of hard start kit and surge protection accessories to help reduce stress. Technician ipad was laying in sun while preformed yearly maintenance and safety checks, when presenting concerns ipad wouldn’t operate for overheating safety, could not present options. Customer would like called with options at earliest convenience.


Robby D.

Robby D. Job Checkin

Performed yearly maintenance and safety checks on 2019 carrier air conditioner unit. Due to ambient temperature technician didn’t let unit run for extended periods of time, also couldn’t get accurate temperature drop. Filter was half sucked into furnace. Customer stated 3 month filter cycle. Technician recommended going to a 1 month cycle. Found excess dirt at bottom of return drop took video and presented to customer. Customer stated they have a duct cleaning company. Did not give out fresh air corp card. Informed customer of air purification systems customer will think about it due to recently having a Child. Unit is within manufacture specifications mechanically. No concerns at this time.