Responded to fireplace having cycling issues. Customer stated he could get pilot lit and stay lit. When flipping switch on wall burners would not ignite. Attempted startup. Pilot had no issues lighting. Upon flipping switch burner ignited properly. Cycled burner multiple times with customer present. Advised customer issue seems intermittent, could be issue with switch or gas valve. Offered switch replacement as preemptive measure. Customer stated he will let go for now since fireplace is working. Will call back if issues persist.
In Winchester, OH, I diagnosed a furnace with a bad blower motor, which was causing the system to fail. Due to the age and condition of the unit, I provided an estimate for the cost of installing a new furnace to ensure reliable heating.
Performed yearly maintenance and safety checks on 17 Bryant furnace. 8.07%o2 43 ppm co in flu. 0 ppm co in supply. 63 degree deltat. Cleaned flame sensor and flu trap. No issues found at this time.
Performed yearly maintenance and safety checks on 18 rheem furnace. 15 kw heat kit pulling 20 kw each. 30/50 deltat. . 45 voltage absorption system reading 44.1. Found transformer warm to touch. Making buzzing noises. Customer will consult with husband and call back if wanting to move forward.
Cost to install air condition and furnace. Cost to install heat pump to get the tax credit.
Performed furnace check on Lennox furnace. Customer had inspector list issues that needed address. Inspector noticed water leaking onto condensation line. Water leaking from suction line having roughly 1 inch of uninsulated pipe. Was able to manipulate insulation to cover line completely. Customer also had concerns with calcification and rust on burners inducer motor and flue pipe. Parts on order, should receive parts within 3-7 business days. Will return when parts arrive to replace corroded parts. 3 ppm co in flu. 10 %o2. Cleaned flame sensor. Will return as soon as possible to make corrections Returned to complete furnace repair. Replaced burners, inducer motor/adapter and flu pipe. Started furnace to confirm operation and saftey. Unit running with 7.2o2 68 degree deltat. No issues upon departure.
Cost to install central air conditioning and furnace. Cost to install humidifier
Cost to install air conditioning
Cost to install air conditioning and furnace
Performed yearly maintenance and safety checks on 19 Bryant ac.replaced 12-24-1 filter. 35/5 voltage absorption system reading 34/5. 70 in Rush amps. No issues found at this time.
Performed yearly maintenance and safety checks on 2000 Rheem air-conditioning system. Found 45/5 orange absorption system reading 45/5. 83 in rush amps. No issues found at this time. Clean 213 filter.
Performed yearly maintenance and safety checks on 13 trane ac system. Found 35/5 reading 34.1/4.9. 88-108 hard start reading 104. No issues at this time 52 degree ambient temperature.
Performed yearly maintenance and safety checks on 2011 Lennox air conditioning system. Found 45/10 voltage absorption system reading 45/10. 67 inrush amps. 88–108 hard start reading 104. Cleaned condenser. Replaced customer supplied 18254