Customer concerned about unit not cooling properly. Customer has mentioned they have reset the breaker and clean drain line with vacuum. Unit is not cooling properly. Checked thermostat calibration and filter location. Checked blower motor operation and inspected equipment cabinet. The evaporator coil is rusty and aged equipment. Located the blower motor is bad and needs to be replaced. The blower motor is to pull in air from return filter and send thruway the evaporator coil and out the ductwork. Need blower motor replacement Bryant Model # Fb4cnf048 Serial # 3414a84840 Checked condenser unit and start up components. The condenser has good refrigerant pressure in the system. Customer would like comfort advisor to come out provided estimate for unit replacement. I have placed an estimate for blower motor replacement Customer has approved for comfort advisor to estimate for unit upgrade. 2500 sq ft. With 4 ton heat pump condenser. Thank you for choosing total air.