Arrived at customer's house for system inspection. On arrival customer showed me to air handler unit. Open up cabinet and saw biogrowth on the motor and on motor wiring. Suggested customer get IAQ you're get IAQ. Customer would like to do research before making decision. You know it was putting out proper Delta T. Under evaporator coil was clean. Next in period next went outside to condenser and hooked up gages. All pressures and readings were of acceptable range. Contact or sending proper voltage. Capacitor within acceptable range. Vacuumed out condensate line. Unit checks out. Gave report to customer and customer was happy with report. Collected payment and signature and left. Customer happy.


wade@totalairinc.net

wade@totalairinc.net Job Checkin

Unit #1 for 2nd floor Upon arrival customer showed me an air handler in the 2nd floor closet that needed turned up. The evap coil is clean. Cleared the condensate with nitrogen and solvent. Checked the system for proper amps and voltage. Went to the condenser the check proper amps and voltage. Recommended a pure air X and surge protector Unit #2 for 1st floor Upon arrival customer showed me an air handler in the 2nd floor closet that needed turned up. The evap coil is clean. Cleared the condensate with nitrogen and solvent. Checked the system for proper amps and voltage. Went to the condenser the check proper amps and voltage. Capacitor under factory specs. Customer needs a elite build. Customer denied all work. Did recommend a pure air x and surge protector.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Upon arrival checked motors, electrical components, and pressures on 2 rheem split closet systems. AH 1 AND 2 both upstairs. Upstairs IV bulb still on but needs replaced. Replaced UV bulb on larger rheem unit AH (both AH next to each other). Cleared draon line and DeltaT excellent. Recommend Surge protectors for both units. Added existing equipment and left systems in good operating condition.


Brian R.

Brian R. Job Checkin

I performed a maintenance. I checked pressures, electrical components and flushed drain line with cleaner. The warranty capacitor was below factory specs, replaced. I noticed the compressor is slightly noisy on start up. Need to keep an eye on this issue. I left the system in good working order..


rigo@totalairinc.net

rigo@totalairinc.net Job Checkin

Installed the filter and a uv light bulb.