3100 39th Ave North
St. Petersburg, FL 33714
727-822-7700

Job Locations
for st. petersburg, fl


Map of St. Petersburg FL
Wade H.

Wade H.


Job Checkin

Run new drain line pvc underneath home to outside of porch to green area. Extension of drain line underneath the home. Insulated the top half in the ac Air handler closet. Glued all fittings with water tight blue pvc glue and straps to keep drain line level. (Pictures taken) Performed ac tune. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Checked blower motor operation and inspected equipment cabinet. Customer has replaced filter. Checked thermostat calibration and discharge temperature. Cleaned and rinsed condenser coil and compressor deck. Checked refrigerant levels and check test start up components. The capacitor has tested good and working properly. The refrigerant levels are good and unit is cooling properly. Checked ductwork connections and inspected attic insulation. The attic insulation is good and tight attic makes it hard to see the ductwork connections. Recommend new germicidal uvc light to prevent biological growth in