9064 Pulsar Court, Suite I
Corona, CA 92883
(951) 344-5596

Local Reviews
for huntington beach, ca

Rated 5.0 out of 5 stars based on 2 customer reviews

Excellent

Shane to the rescue. He explained the problem he found. He gave me reasonable solutions. He completed the job in the time he quoted. Quality work. Very organized work site. Clean work all around. Very considerate of my home.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Shane was very knowledgeable. He gave an educated and honest assessment of my plumbing problem. I felt confident to schedule to have the work done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for huntington beach, ca

Bob O.

Bob O. Job Checkin

All roof mounted units with electrical supplied to each AC unit Customer to provide crane and customer to pull their own permit Additional zones for the 3 ton units are $3550 Installation Package Includes: • Furnish and install stated equipment as well as all parts, materials and labor at or above manufactures specifications and local code requirements. • New Electrical Disconnect • New Electrical Whip/Power wire from disconnect/switch to new equipment • Proper Size Fuses • New Condenser Pad, level and square • New Gas flex and piping per specs & codes • Condensate drains, both primary & secondary including clean-out tee, trap and electronic safety switch. • Emergency Drain Pan installed under coil (attic installs) • Clean & Chemically Flush existing line-set • Pressure test all refrigerant connections & piping to insure the new system is free of any leaks. • Haul away all jobsite trash and old equipment • Sales Tax is included Warranties: • 10 year parts • 10 year


Shane B.

Shane B. Job Checkin

Demo concrete 45ft of concerete along the side of the house. Demo two access points in the stucco. Excavation soil and installation of new 2” drain line for the laundry and the kitchen sink. Install pipe at 2% grade per code requirements. Rebuild the drain piping under the kitchen sink and reconnect to new provided clean out and sanatary tee. Reconnect to existing vent. Rebuild stack raiser for the laundry room. Install new clean out and reconnect to the exising p-trap with new sanatery waste tee. Reconnect to existing vent. Excavate main swere line in the front yard planter 4ft deep and connect new 2" pipe. Stucco and concrete to be reapired by other.


Bob O.

Bob O. Job Checkin

Provide estimates next week


Shane B.

Shane B. Job Checkin

Dig up In guest bathroom access pipe. Repair pipe, remove camera from line.


Shane B.

Shane B. Job Checkin

Camera was stuck 19ft in. Tried to pull camera out with no success


Bob O.

Bob O. Job Checkin

LEAK DETECTION REPORT Breached concrete and located 3/4" hot water line that burst inside the concrete slab 1" below the top of the concrete. Base on the amount of water leaking, and the amount of water damage to the home, the water was leaking for approximately 6hrs before discovery.