Excellent service and timely.

I had a leak from prior service however they immediately responded and solved it very quickly and for the water damage their resolving too. They really take care of you even with warranty work. Their the best hard to find service like that. Employees are great too.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Tim was very professional and knowledgeable. Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Customer Service Excellent

Representative was very professional, knowledgeable, and informative. Gabriel Baro(RT Olson Plumbing manager) displayed the ultimate in the customer service interaction. He is an asset.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for moreno valley, ca

Shane B.

Shane B. Job Checkin

Fix the hot water tee


Bob O.

Bob O. Job Checkin

Provided solution. Sent to email he will call us back when he gets insurance money


Bob O.

Bob O. Job Checkin

Monthly inspection Patient restroom- functioning as designed toilet bolts loosening recommend pull and reset of toilet so wax ring doesn’t fail. Patient room #1 - slow draining on wash station, some corrosion on angle stops, functioning as designed. Patient room#2- functions as designed. corrosion found on anglestops Water Heater closet- cold water supply for water heater has corrosion on inlet pipe, (recommend immediate replacement on that pipe.) spots are starting to form clear indication of pin hole waiting to happen. Mop sink cracked wasn’t able to test mop sink faucet. (Recommend replacement of mop sink. Pt Prep Room- functioning as designed. Pt Prep Room- toilet bolts loose (recommend pull and Reset of toilet.) slow drain on sink in restroom. Recommend snaking Break Area- functioning as designed Lab Room- functioning as designed has old style gate valves, flushed eye wash station. BullPen- faucet functioning as designed, drain slow to drain(recommend snaking to re adjust feari


Bob O.

Bob O. Job Checkin

Added 1 lb of refrigerant R410a Sealed supply plenum. Everything is working well after the minor repair. System cooling by 21 degrees


Guerrero G.

Guerrero G. Job Checkin

Customer will look at estimates and make decision


Guerrero G.

Guerrero G. Job Checkin

Leak is coming from upstairs shower, drain customer would talk to husband and schedule for either Friday or Monday


Guerrero G.

Guerrero G. Job Checkin

Detection. No meter spinning no toilet running. Customer will call us when meter spins. Found a couple plumbing repairs sent customer estimate.


Guerrero G.

Guerrero G. Job Checkin

Faucet supply line leaking


Guerrero G.

Guerrero G. Job Checkin

Cable and hydro jet line


Bob O.

Bob O. Job Checkin

Crossover health, Moreno Valley W/H Check valve has a little bit of corrosion on top Cold side, inlet, dielectric union has corrosion/calcification buildup Little bit of buildup calcification on research pump Water heater flush 3 flashings a lot of calcium build up shot out. PT Prep room inspected PT, prep prep room everything functions as designed Restroom near pt Toilet angle, stop shutting off as design lavatory faucet shut off’s working as designed faucet mix. It has corrosion on top and bottom portions. Flushed lines Toilet will need a pull and reset, tech tightened down bolts. Break room, shut offs functioning as designed kitchen sink, and break room, functioning as designed Flushed lines. Lab room has a gate valve. Gate vale angle stops not shutting off correctly. Advise change to quarter stop angle stop Flushed lines Bullpen sink, house, gate valve style angle stops functiong as designed Eyewash station flushed Lines flushed Patient room bug functioning as design. fun


Bob O.

Bob O. Job Checkin

Technician came out to shut off valve to mop sink, mops sink had crack recommend replacement


Bob O.

Bob O. Job Checkin

Technician showed up to see water coming out through clean out plug. Notice of 2 holes on clean out plug Tech determined that the sewer line is backing up. Tech replaced clean out plug with new plug and snaked line up too 25’ pulled out used tampon from line causing back up. Upon cleaning up tech notice water coming from pop up assembly tech had to pull and reset pop up with new putty and tighten up all loose ends.


Bob O.

Bob O. Job Checkin

Cross over Moreno Valley Front Bathroom is functioning as designed Pt prep Sink is functioning as designed Maintenance closet is functioning @s designed. Water heater cold water inlet has corrosion still in working order how ever would recommend replacement of section. Pt Prep restroom has loose faucet needs to be tighten. Toilet needs to be pulled and rest due to loose bolts could cause wax ring to fail and have sewage flood out. Bull pen kitchen is functioning as designed Bull pen sink is functioning as designed, eye w1h station is loose must be tightened up. Recommend replacement of gate valve style angle stops to be replaced with 1/4” turn angle stops Lab room sink functioning as designed, eyes wash station needs to be tightened. Recommend replacement of gate valve style angle stops to be replaced with 1/4” turn angle stops Patient room bug functioning as designed faucet loose needs tightening Patient room mustang functioning as designed


Bob O.

Bob O. Job Checkin

Leaking faucet


Bob O.

Bob O. Job Checkin

Performed inspection at Moreno VALLEY. Patient room1: sink faucet functional as designed. 1/4 turn angle stops functioning as designed. Drain properly functioning Patient room2: sink faucet functional as designed. 1/4 turn angle stops functioning as designed. Drain properly functioning Water heater closet: water heater functioning as designed, notice of corrosion at nipples of exiting water of heater. Water heater recirculating pump functioning as designed. Mop sink draining as designed. Mop sink faucet functioning s designed. Lab: Faucet: Sink faucet functional as designed. 1/4 turn angle stops functioning as designed. Drain properly functioning. Eye wash station working properly. And at desired temperature. Bullpen: sink faucet functional as designed. 1/4 turn angle stops functioning as designed. Drain properly functioning. Eye wash station functioning as designed. Bathroom: sink faucet functional as designed. 1/4 turn angle stops functioning as designed. Drain properly fun