I performed a 2 system heating maintenance on gas systems. Zoned communicating Amana- furnace 2020 - condenser 2024 Trane - Furnace 2020 - condenser 2016 I checked amps, capacitors, filters, electrical, cleanliness, temperature split, and safeties. Systems are heating inside of manufacture specifications. Customer mentioned some uneven cooling/heating in areas of the home. I investigated into the matter. I found the source of the issue. There is a single duct that splits 3 ways to the rooms in question. To properly address this issue, we would need to redesign to ducting system. I observed that the filters don’t fully seal in the filter cabinet. This causes dust to bypass into the system and making components dirty and strain. I advise that the filter cabinet be upgraded to allow a filter that will perfectly fit. The units do not have surge protection and risk damage if power fluctuates. Customer approved work to be performed and prefers after Christmas. Collected in full for the wor