Came out for 1 system maintenance. Upon arrival started with indoor upflow gas unit, our install. Customer changes filters themselves, checked all heating elements to verify proper heating sequence. All safeties are operating as designed, burners are firing properly. Washed out unit and checked all electrical components. All components are operating as designed. Recommend adding pan treatment into system to treat drain line to help prevent issues from occurring. Also recommend adding hard start kit and surge protection to improve longevity of system and to protect unit. Thank you for your time. Pan treatment
Performed one time fall tune-up on 3 year old system. Found blower assembly dirty due to poor quality of filter (fiberglass), recommend pleated filters MERV rating 8-12. No further mechanical issues. System is heating home properly and safely at this time. Filter Fetch website - https://filterfetch.com/contractor-link/CDK8 Filter size is 16x25x1
Performed one time spring tuneup and found a few areas of concern for indoor air quality, system efficiency and components. Please refer to estimate emailed to client. Outdoor unit is 80%-90% clogged with debris, indoor unit has pet hair debris under unit where return air is going to system, indoor blower motor run capacitor is weak and could pose a failure in future use. Replaced run capacitor with MiniTurbo (5 year warranty)